Application Note 3. DSP Packet Recording
Version 2.6.1 7 June 2008
2.3 System and Security Logging
The System and Security Logging configuration remains the same as in previous versions
(refer to the MP-202 Telephone Adapter User's Manual) – and affects debug messages
that are not related to the VoIP application.
¾ To activate the log level option:
1. In the left-side bar, click the Advanced icon, and then select the System Settings
icon.
2. In the 'System Logging' and 'Security Logging' sections, choose the logging level.
Figure 2-3: System and Security Logging
To view the System and Security Logging, browse to 'System Monitoring' screen ->
'System Log'.
2.4 Configuration File
The MP-20x allows you to view, save, and load its configuration file to backup and restore
your current configuration. Please refer to the MP-20x Telephone Adapter User's Manual
for additional information regarding this feature.
3 DSP Packet Recording
The Packet Recording feature enables the recording of all packets transmitted and
received by the MP-20x DSP. This feature is essential for efficient debugging. The
recorded packets are transmitted to the host through the network port and can be captured
using the Ethereal or Wireshark capturing tools. If you are requested to capture packet
recording, please send the capture to AudioCodes for analysis.
¾ To activate the Packet Recording tool:
1. Open a Telnet session with the MP-20x.
2. Start the Ethereal or Wireshark applications located on your host PC.
3. Activate packet recording, by typing the following command:
dsp_cmd pr <ch_id> <start/stop> <host IP> <host IP> <host IP>
<host IP>