Debugging and Diagnostic Tools 6 Document #: LTRT-58201
2.2 Log Level Option
When this parameter is enabled, SIP messages are visible in the 'System Log' screen.
¾ To activate the log level option:
1. Open a Telnet session to the MP-20x.
2. At the prompt, type the following command:
voip_set_log_level 1
3. To view the SIP messages, click the System Monitoring menu, and then click the
System Log tab.
4. To disable this feature, type the following command:
voip_set_log_level 0
Figure 2-2: SIP Messages in the 'System Monitoring - System Log' Screen